OPTIBAR DP 3050

Differential pressure transmitter for general flow, level and differential pressure applications

  • The most compact design in its class
  • Measuring ranges: 100 mbar…16 bar / 1.45…232 psi; Line pressure: up to 160 bar / 2320 psi
  • Reference accuracy ± 0.1%
  • 2-wire, 4…20 mA/HART®7

OPTIBAR DP 3050

Differential pressure transmitter for general flow, level and differential pressure applications

  • The most compact design in its class
  • Measuring ranges: 100 mbar…16 bar / 1.45…232 psi; Line pressure: up to 160 bar / 2320 psi
  • Reference accuracy ± 0.1%
  • 2-wire, 4…20 mA/HART®7

Related products

OPTIBAR DSD 3100

Diaphragm seal with flange design and optional extension

  • Direct attachment to OPTIBAR DP 7060 differential pressure transmitter
  • Flange: DN50…100 / 2…4"; max. PN63 / ASME Cl 300
  • Up to +150°C / +302°F
  • Wetted materials for aggressive, corrosive, viscous, solidifying or abrasive media

OPTIBAR DSD 3110

Diaphragm seal with flange design and optional extension

  • Capillary tube attachment to OPTIBAR DP 7060 differential pressure transmitter
  • Flange: DN50…100 / 2…4"; max. PN63 / ASME Cl 300
  • Up to +400°C / +752°F
  • Wetted materials for aggressive, corrosive, viscous, solidifying or abrasive media

OPTIBAR DSD 3210

Diaphragm seal with flange design and optional extension

  • Direct and capillary tube attachment to OPTIBAR DP 7060 differential pressure transmitter
  • Flange: DN50…100 / 2…4"; max. PN63 / ASME Cl 300
  • Up to +400°C / +752°F
  • Wetted materials for aggressive, corrosive, viscous, solidifying or abrasive media

OPTIBAR DSD 3220

Diaphragm seal with flange design and optional extension

  • 2 x capillary tube attachment to OPTIBAR DP 7060 differential pressure transmitter
  • Flange: DN50…100 / 2…4"; max. PN63 / ASME Cl 300
  • Up to +400°C / +752°F
  • Wetted materials for aggressive, corrosive, viscous, solidifying or abrasive media

OPTIBAR OP 1100

Orifice plate with RF sealing face

  • For mounting between measuring flanges (ASME 16.36, 16.5, 16.47 A)
  • Size: ½…24"; up to ASME Cl 2500
  • Temperature: up to +450°C / +842°F
  • Material: 1.4404 / 316L

OPTIBAR OP 1110

Orifice plate with RTJ sealing face

  • For mounting between measuring flanges (ASME 16.36, 16.5)
  • Size: 1…24"; up to ASME Cl 2500
  • Temperature: up to +450°C / +842°F
  • Material: 1.4404 / 316L

OPTIBAR OP 3100

Orifice plate with flat sealing face and corner taps

  • Separate type, with carrier ring and optional shut-off valve
  • Size: DN50…600; up to PN100
  • Temperature: up to +400°C / +752°F
  • Material: 1.4404 / 316L

OPTIBAR OP 3200

Orifice plate with flat sealing face and corner taps

  • Compact type, with carrier ring, flange plate and optional manifold
  • Size: DN50…600; up to PN100
  • Temperature: up to +400°C / +752°F
  • Material: 1.4404 / 316L

OPTIBAR OP 4100

Orifice plate with annular chamber and corner taps

  • Separate type, for installation between standard flanges (EN 1092-1), optional shut-off valves
  • Size: DN50…600; up to PN100
  • Temperature: up to +400°C / +752°F
  • Material: 1.4404 / 316L

OPTIBAR OP 5100

Orifice assembly with measuring flanges (ASME 16.36)

  • With RF sealing face and flange taps
  • Size: 1…24"; up to ASME Cl 2500
  • Temperature: up to +400°C / +752°F
  • Material: 1.4404 / 316L

OPTIBAR OP 5110

Orifice assembly with measuring flanges (ASME 16.36)

  • With RTJ sealing face and flange taps
  • Size: 1…24"; up to ASME Cl 2500
  • Temperature: up to +400°C / +752°F
  • Material: 1.4404 / 316L

OPTIBAR PT 2000

Averaging pitot tube with multiple impact-sensing ports

  • Low pressure loss design; from basic to engineered solutions
  • Cryogenic to high temperatures possible (-200…+1000°C / -328…+1832°F); max. 160 bar / 2320.1 psi
  • For line sizes from DN50…2000 / 2…80" (larger on request)
  • Material: 1.4404 / 316L

Flow nozzle

Engineered primary element for DP flow measurement of high velocity, non-viscous or erosive fluids

  • ISA 1932, long radius and Venturi nozzles
  • Standards: ISO 5167, ASME MFC-3M or ASME PTC 6
  • Only short inlet and outlet runs required

Venturi tube

Engineered primary element for DP flow measurement of liquids, gases and steam with the lowest residual pressure loss

  • Machined or welded design (internally machined) according to EN ISO 5167, ASME MFC3
  • Lowest residual pressure loss of all DP elements
  • Only short inlet/outlet runs required
  • From basic to special wet gas applications and high pressure conditions

Cone meter

Engineered primary element for DP flow measurement in applications with limited installation space

  • Meter run with integrated cone and single taps according to EN ISO 5167-4
  • Rugged solution for difficult media and harsh operating conditions, e.g. in oil and gas applications
  • Designed for large diameters (up to 24″), demanding flow profiles, high pressures and temperatures

Wedge meter

Engineered primary element for DP flow measurement of high viscous and solids-containing fluids

  • Meter run with integrated V-shaped wedge
  • For slurry and fibrous liquids containing solids or gases
  • Reynolds number down to 300
  • Applicable for bi-directional measurement
Email
Contact