MAC 100

Liquid analytical transmitter for measurements with sensors of the OPTISENS portfolio

  • Output: 3 x 4…20 mA, 3 relays (mechanical)
  • Input: max. 2 x sensor, 2 x temperature
  • -15…+55°C / +5…+131°F (ambient)
  • Robust housing for wall-mount installation

MAC 100

Liquid analytical transmitter for measurements with sensors of the OPTISENS portfolio

  • Output: 3 x 4…20 mA, 3 relays (mechanical)
  • Input: max. 2 x sensor, 2 x temperature
  • -15…+55°C / +5…+131°F (ambient)
  • Robust housing for wall-mount installation

Related products

OPTISENS PH 8100

Potentiometric pH sensor for chemicals, industrial wastewater and low conductivity media (>2 μS/cm)

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +130°C / +266°F; 10 bar / 145 psi
  • Glass sensor with 2 open diaphragms and Pt100 for temperature compensation

OPTISENS PH 8300

Potentiometric pH sensor for wastewater, surface and process water applications

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +70°C / +158°F; 10 bar / 145 psi
  • Glass sensor with PTFE diaphragm and optional Pt100 for temperature compensation

OPTISENS PH 8390

Potentiometric pH sensor for municipal and industrial wastewater applications

  • For use with analytical transmitter
  • Process connection: ¾ NPT (male)
  • 0…14 pH; Max. +80°C / +176°F; 6.9 bar / 100 psi
  • With CPVC sensor body, PTFE diaphragm and Pt100 for temperature compensation

OPTISENS PH 8500

Potentiometric pH sensor for potable water applications

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +70°C / +158°F; 2 bar / 30 psi
  • Glass sensor with ceramic diaphragm and optional Pt100 for temperature compensation

OPTISENS PH 8590

Potentiometric pH sensor for water and wastewater applications

  • For use with analytical transmitter
  • Process connection: ¾ NPT (male)
  • 0…14 pH; Max. +80°C / +176°F; 6.9 bar / 100 psi
  • With CPVC sensor body, ceramic diaphragm and Pt100 for temperature compensation

OPTISENS PH 9100

Potentiometric pH sensor for lower conductivity water applications (>20 μS/cm)

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +100°C / +212°F; 1 bar / 14 psi
  • Liquid electrolyte glass sensor with open glass sleeve diaphragm

OPTISENS PH 9500

Potentiometric pH sensor for lower conductivity water applications (>50 μS/cm)

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +100°C / +212°F ; 1 bar / 14 psi
  • Liquid electrolyte glass sensor with 3 ceramic diaphragms

OPTISENS ORP 8500

Potentiometric ORP sensor for water and wastewater applications

  • For use with analytical transmitter
  • Process connection: PG13.5
  • -1500…+1500 mV; Max. +70°C / +158°F; 2 bar / 30 psi
  • Glass sensor with platinum electrode and ceramic diaphragm

OPTISENS ORP 8590

Potentiometric ORP sensor for water and wastewater applications

  • For use with analytical transmitter
  • Process connection: ¾ NPT (male)
  • -2000…+2000 mV; Max. +80°C / +176°F; 6.9 bar / 100 psi
  • Sensor with CPVC body, platinum electrode, ceramic diaphragm and Pt100 temperature sensor

OPTISENS COND 1200

Conductive conductivity sensor for water, wastewater, process water or pure water

  • For use with analytical transmitter
  • Process connection: G½, G¾, G1, ¾ NPT (male)
  • 0.05 μS/cm…20 mS/cm; Max. +135°C / +275°F
  • With two stainless steel, titanium or graphite electrodes and Pt100 for temperature compensation

OPTISENS COND 7200

Conductive conductivity sensor for hygienic applications

  • For use with analytical transmitter
  • Process connection: Clamp DN25-40, 1½"
  • 0.05…1000 μS/cm; Max. +135°C / +275°F
  • Short or long version with stainless steel electrodes and Pt100 for temperature compensation

OPTISENS IND 1000

Inductive conductivity sensor for water, wastewater and chemical applications

  • For use with analytical transmitter
  • Process connection: G1½ union nut and immersion versions
  • 1…2000 mS/cm; Max. +100°C / +212°F
  • Electrodeless conductivity sensor with Pt1000 for temperature compensation

OPTISENS IND 7000

Inductive conductivity sensor for food and beverage applications

  • For use with analytical transmitter
  • Process connection: Dairy screw (DIN 11851) DN50 and DN65, VARIVENT® N, G1½ or G2 (male, non-hygienic)
  • 0.5…2000 mS/cm; Max. +125°C / +257°F (for SIP/CIP); 10 bar / 145 psi
  • Sterilisable PEEK sensor (FDA and EC1935/2004 conform) with temperature compensation

OPTISENS TSS 2000

Optical total suspended solids sensor for wastewater applications

  • For use with MAC 100 analytical transmitter
  • For immersion
  • 0…4 AU, 0…18.5 g/l (sludge); max. +70°C / +158°F; 1 bar / 14 psi
  • Robust stainless steel sensor using single beam (180° NIR LED) principle, with optical sapphire glass windows

OPTISENS ADO 2000

Amperometric oxygen sensor for water and wastewater applications

  • For use with analytical transmitter
  • For immersion or insertion
  • 0…20 mg/l; Max. +50°C / +122°F; 6 bar / 87 psi
  • With stainless steel sensor body, rugged PTFE membrane, exchangeable electrode cartridge and temperature compensation

OPTISENS ODO 2000

Optical oxygen sensor for water and wastewater applications

  • 2-wire loop powered, 4…20 mA or Modbus for direct connection to a PCS; calibration and configuration via Modbus or with MAC 100 transmitter
  • For immersion or insertion
  • 0…20 mg/l; Max +50°C / +122°F; 6 bar / 87 psi
  • With rugged PVC sensor body, available with spray cleaning nozzle (immersion version)

OPTISENS CL 1100

Potentiostatic amperometric disinfectant sensor for water and wastewater applications

  • For use with MAC 100 analytical transmitter
  • Process connection: PG13.5
  • Cl2: 0.03…20 mg/l; ClO2: 0.05…5  mg/l; O3: 0.05…5 mg/l; Max. +70°C / +158°F; 6 bar / 87 psi
  • Membrane-free sensor with 2 gold electrodes and sensor cleaning feature

OPTISYS CL 1100

Potentiostatic amperometric disinfectant measuring system for water and wastewater applications

  • Completely mounted with MAC 100 analytical transmitter (Output: 3 x 4…20 mA)
  • Pre-installed and tested; for bypass lines
  • Cl2: 0.03…20 mg/l; ClO2: 0.05…5 mg/l; O3: 0.05…5 mg/l; Max. +50°C / +122°F; 6 bar / 87 psi
  • With chlorine sensor, valves, flow cells, optional pH sensor
Email
Contact
Live chat