OPTIBAR DP 7060

Differential pressure transmitter for flow, level, differential pressure, density and interface measurements

  • High performance DP transmitter with integrated line pressure measurement
  • Measuring range: 30 mbar…16bar / 0.44…232 psi; Line pressure: up to 700 bar / 10,153 psi
  • Reference accuracy of ±0.065%
  • 2-wire, 4…20 mA/HART®, FF, Profibus-PA, Bluetooth®

OPTIBAR DP 7060

Differential pressure transmitter for flow, level, differential pressure, density and interface measurements

  • High performance DP transmitter with integrated line pressure measurement
  • Measuring range: 30 mbar…16bar / 0.44…232 psi; Line pressure: up to 700 bar / 10,153 psi
  • Reference accuracy of ±0.065%
  • 2-wire, 4…20 mA/HART®, FF, Profibus-PA, Bluetooth®

Related products

OPTICHECK Pressure Mobile

Mobile app for pressure transmitters

  • Works with all OPTIBAR PM 5060, OPTIBAR PC 5060 and OPTIBAR DP 7060 equipped with Bluetooth display and adjustment module
  • Wireless device commissioning, verification and monitoring even in hard-to-reach areas
  • Parameterisation similar to PACTware DTM including remote SIL mode activation
  • Free download for iOS and Android

Compact orifice plate flowmeter

Integral DP flowmeter for liquids, gases and steam

  • Fast and easy installation without additional engineering, impulse lines and supports
  • Up to +400°C / +752°F; max. 160 bar / 2320 psi (line pressure)
  • Line size: DN50…600 / 2…24"
  • 2-wire 4…20 mA/HART®, FF, Profibus-PA

Integral orifice meter run assembly

DP flowmeter for process applications with small line sizes (down to DN15 / ½")

  • Standardised calibrated meter run assembly, designed acc. to ISO 5167 or ISO TR 15377
  • Up to +400°C / +752°F; max. 160 bar / 2320 psi (line pressure)
  • Flange: DN15…100 / ½...4"
  • 2-wire, 4…20 mA/HART®, FF, Profibus-PA

Averaging pitot tube flowmeter

DP flowmeter for applications with liquids, gases and steam to high-temperature applications with dust-laden gases

  • Fast and easy installation without additional engineering, impulse lines and supports; the best retrofit capability
  • -200…+1150°C / -328…2102°F; max. 320 bar / 4641.2 psi (line pressure)
  • For line sizes DN50…2000 / 2…80" (larger on request)
  • 2-wire 4…20 mA/HART®, FF, Profibus-PA

OPTIBAR DP 7060
with diaphragm seal

Differential pressure transmitter for advanced applications and high temperatures

  • Continuous measurement of differential pressure, level, density and interface
  • Different diaphragm seals for corrosive, viscous or reducing media and vibration
  • Thread: ¼ NPT; Flange: DN50…100 / 2…4"
  • Measuring range: max. 16 psig / 232 psig; max. +400°C / +752°F

SHD 200

Control unit for 4…20 mA/HART® field devices

  • Second 4…20 mA output for any HART® variable
  • 2 configurable relays for status output, system alarm or limit switch
  • Status signalisation by 5 LEDs according to NAMUR NE 107
  • User-configurable measurement pages for all 4…20 mA and HART® signals incl. trend graph and summary page

OPTIBAR DSD 3100

Diaphragm seal with flange design and optional extension

  • Direct attachment to OPTIBAR DP 7060 differential pressure transmitter
  • Flange: DN50…100 / 2…4"; max. PN63 / ASME Cl 300
  • Up to +150°C / +302°F
  • Wetted materials for aggressive, corrosive, viscous, solidifying or abrasive media

OPTIBAR DSD 3110

Diaphragm seal with flange design and optional extension

  • Capillary tube attachment to OPTIBAR DP 7060 differential pressure transmitter
  • Flange: DN50…100 / 2…4"; max. PN63 / ASME Cl 300
  • Up to +400°C / +752°F
  • Wetted materials for aggressive, corrosive, viscous, solidifying or abrasive media

OPTIBAR DSD 3210

Diaphragm seal with flange design and optional extension

  • Direct and capillary tube attachment to OPTIBAR DP 7060 differential pressure transmitter
  • Flange: DN50…100 / 2…4"; max. PN63 / ASME Cl 300
  • Up to +400°C / +752°F
  • Wetted materials for aggressive, corrosive, viscous, solidifying or abrasive media

OPTIBAR DSD 3220

Diaphragm seal with flange design and optional extension

  • 2 x capillary tube attachment to OPTIBAR DP 7060 differential pressure transmitter
  • Flange: DN50…100 / 2…4"; max. PN63 / ASME Cl 300
  • Up to +400°C / +752°F
  • Wetted materials for aggressive, corrosive, viscous, solidifying or abrasive media

OPTIBAR OP 1100

Orifice plate with RF sealing face

  • For mounting between measuring flanges (ASME 16.36, 16.5, 16.47 A)
  • Size: ½…24"; up to ASME Cl 2500
  • Temperature: up to +450°C / +842°F
  • Material: 1.4404 / 316L

OPTIBAR OP 1110

Orifice plate with RTJ sealing face

  • For mounting between measuring flanges (ASME 16.36, 16.5)
  • Size: 1…24"; up to ASME Cl 2500
  • Temperature: up to +450°C / +842°F
  • Material: 1.4404 / 316L

OPTIBAR OP 3100

Orifice plate with flat sealing face and corner taps

  • Separate type, with carrier ring and optional shut-off valve
  • Size: DN50…600; up to PN100
  • Temperature: up to +400°C / +752°F
  • Material: 1.4404 / 316L

OPTIBAR OP 3200

Orifice plate with flat sealing face and corner taps

  • Compact type, with carrier ring, flange plate and optional manifold
  • Size: DN50…600; up to PN100
  • Temperature: up to +400°C / +752°F
  • Material: 1.4404 / 316L

OPTIBAR OP 4100

Orifice plate with annular chamber and corner taps

  • Separate type, for installation between standard flanges (EN 1092-1), optional shut-off valves
  • Size: DN50…600; up to PN100
  • Temperature: up to +400°C / +752°F
  • Material: 1.4404 / 316L

OPTIBAR OP 5100

Orifice assembly with measuring flanges (ASME 16.36)

  • With RF sealing face and flange taps
  • Size: 1…24"; up to ASME Cl 2500
  • Temperature: up to +400°C / +752°F
  • Material: 1.4404 / 316L

OPTIBAR OP 5110

Orifice assembly with measuring flanges (ASME 16.36)

  • With RTJ sealing face and flange taps
  • Size: 1…24"; up to ASME Cl 2500
  • Temperature: up to +400°C / +752°F
  • Material: 1.4404 / 316L

OPTIBAR MR 4300

Orifice meter run with corner taps and annular chambers

  • Completely pre-assembled with orifice plate, piping, inlet/outlet sections, process connections
  • Size: DN15…100 / ½…4"; up to PN100 / ASME Cl 1500
  • Temperature: max. +400°C / +752°F
  • Material: 1.4404 / 316L

OPTIBAR PT 2000

Averaging pitot tube with multiple impact-sensing ports

  • Low pressure loss design; from basic to engineered solutions
  • Cryogenic to high temperatures possible (-200…+1000°C / -328…+1832°F); max. 160 bar / 2320.1 psi
  • For line sizes from DN50…2000 / 2…80" (larger on request)
  • Material: 1.4404 / 316L

Flow nozzle

Engineered primary element for DP flow measurement of high velocity, non-viscous or erosive fluids

  • ISA 1932, long radius and Venturi nozzles
  • Standards: ISO 5167, ASME MFC-3M or ASME PTC 6
  • Only short inlet and outlet runs required

Venturi tube

Engineered primary element for DP flow measurement of liquids, gases and steam with the lowest residual pressure loss

  • Machined or welded design (internally machined) according to EN ISO 5167, ASME MFC3
  • Lowest residual pressure loss of all DP elements
  • Only short inlet/outlet runs required
  • From basic to special wet gas applications and high pressure conditions

Cone meter

Engineered primary element for DP flow measurement in applications with limited installation space

  • Meter run with integrated cone and single taps according to EN ISO 5167-4
  • Rugged solution for difficult media and harsh operating conditions, e.g. in oil and gas applications
  • Designed for large diameters (up to 24″), demanding flow profiles, high pressures and temperatures

Wedge meter

Engineered primary element for DP flow measurement of high viscous and solids-containing fluids

  • Meter run with integrated V-shaped wedge
  • For slurry and fibrous liquids containing solids or gases
  • Reynolds number down to 300
  • Applicable for bi-directional measurement
Email
Contact
Live chat